content loaded
LOCHINVAR WHB155N Image 1

LOCHINVAR WHB155N WLL/MNT KNIGHT 150 BTU CNDSNG BOILER

MFR Part #: WHB155N
SKU #: 1244089
Brand: Lochinvar®
UPC: 067165092996
Lochinvar® WHB155N Residential Gas Boiler, 95 % AFUE, 535 mbh Capacity, 120 VAC, 1 ph Phase, Natural Gas Fuel
15 Year Limited
For hot water

Lochinvar® Residential Gas Boiler, 120 VAC, 60 Hz Frequency, 1 ph, 95 % AFUE, 535 mbh Capacity, 9 gpm Flow Rate, 80 psi Pressure, Natural Gas Fuel, Direct, Horizontal, Vertical Vent, Low NOx, Modulating Burner, Direct Spark Ignition, Wall Mounting, Dimensions: 19-1/8 in L x 18-3/4 in W x 41-3/4 in H, Additional Information: 1/2 in Connection, 30 psi ASME 3/4 in Relief Valve, 9 gpm at 35 deg F gph Recovery

With over 100000 units sold to date, the KNIGHT boiler line has continued to benefit from Lochinvar®'s commitment to perpetual innovation with four model generations and a host of design, efficiency and installation enhancements.

Product Details

Lochinvar® Residential Gas Boiler, 120 VAC, 60 Hz Frequency, 1 ph, 95 % AFUE, 535 mbh Capacity, 9 gpm Flow Rate, 80 psi Pressure, Natural Gas Fuel, Direct, Horizontal, Vertical Vent, Low NOx, Modulating Burner, Direct Spark Ignition, Wall Mounting, Dimensions: 19-1/8 in L x 18-3/4 in W x 41-3/4 in H, Additional Information: 1/2 in Connection, 30 psi ASME 3/4 in Relief Valve, 9 gpm at 35 deg F gph Recovery

With over 100000 units sold to date, the KNIGHT boiler line has continued to benefit from Lochinvar®'s commitment to perpetual innovation with four model generations and a host of design, efficiency and installation enhancements.

Attributes

AFUE Rating95 %
Burner TypeLow Nox, Modulating
Capacity535 mbh
Dimensions19-1/8 in L x 18-3/4 in W x 41-3/4 in H
Flow Rate9 gpm
Frequency Rating60 Hz
Fuel TypeNatural Gas
Ignition TypeDirect Spark
Mounting TypeWall
Phase1 ph
Pressure Rating80 psi
Vent TypeDirect, Horizontal, Vertical
Voltage Rating120 VAC
Additional Information1/2 in Connection, 30 psi ASME 3/4 in Relief Valve, 9 gpm at 35 deg F gph Recovery

Features

  • Multi-color graphic LCD display with navigation dial, soft keys and Loch-N-Link USB programming
  • Three-boiler set point temperature inputs, Plus domestic hot water prioritization
  • Multiple size boiler cascade
  • Lead lag
  • Efficiency optimization
  • Front end loading capability
  • Programmable for three-reset temperature input
  • SH night setback
  • DHW night setback
  • Anti-cycling
  • Outdoor air reset curve
  • Ramp delay
  • Modulation factor control
  • Boost temperature and time
  • System pump with parameter for continuous operation
  • Boiler pump with variable speed control
  • Domestic hot water pump
  • Domestic hot water recirculation
  • DHW tank piped with priority in the boiler loop
  • DHW tank piped as a zone in the system with the pumps controlled by the smart system DHW modulation limiting