Bradford White® Brute™ BJVS100NDJSU2 Mini Hydronic Boiler, Natural Gas Fuel, 100000 Btu/hr Input, Built-In Draft Diverter Vent, 1-1/4 in NPT Water/3/4 in NPT Gas Connection, Spark Pilot Ignition
20 Years Limited
Residential
ASME Specified|AHRI Certified|CSA Certified|cCSAus Listed

Bradford White® Brute™ Mini Hydronic Boiler, Natural Gas Fuel, 100000 Btu/hr Input, 1-1/4 in NPT Water/3/4 in NPT Gas Connection, Spark Pilot Ignition, 85 MBtu/hr DOE Heating, 85 % AFUE, 115 VAC, >12 A, 6 in Flue Outlet, Built-In Draft Diverter Vent, 27-1/2 in D x 28-3/4 in H

Brute™ Mini's simple design, compact size and unique 2-stage firing (standard on all 100-225 models) can improve comfort and heating efficiency in nearly any hydronic system. All Brute™ Mini models comply with DOE 2012 minimum efficiency requirements for residential boilers and are factory-equipped with user-friendly boiler reset control system.

Product Details

Bradford White® Brute™ Mini Hydronic Boiler, Natural Gas Fuel, 100000 Btu/hr Input, 1-1/4 in NPT Water/3/4 in NPT Gas Connection, Spark Pilot Ignition, 85 MBtu/hr DOE Heating, 85 % AFUE, 115 VAC, >12 A, 6 in Flue Outlet, Built-In Draft Diverter Vent, 27-1/2 in D x 28-3/4 in H

Brute™ Mini's simple design, compact size and unique 2-stage firing (standard on all 100-225 models) can improve comfort and heating efficiency in nearly any hydronic system. All Brute™ Mini models comply with DOE 2012 minimum efficiency requirements for residential boilers and are factory-equipped with user-friendly boiler reset control system.

Attributes

AFUE Rating85 %
Amperage Rating>12 A
Connection Type1-1/4 in NPT Water/3/4 in NPT Gas
Dimensions27-1/2 in D x 28-3/4 in H
DOE Heating Capacity85 MBtu/hr
Flue Outlet Size6 in
Fuel TypeNatural Gas
Ignition TypeSpark Pilot
Input Capacity100000 Btu/hr
Vent TypeBuilt-In Draft Diverter
Voltage Rating115 VAC

Features

  • PI controller
  • Outdoor reset with ratios of 0.4 to 3.6
  • Indicator lights for power, heat call, DHW call and WWSD
  • Automatic boiler differential
  • Pump pre-purge, post-purge and exercise
  • Codes for sensor errors
  • Pressure relief valve: capacity in excess of boiler input rating
  • Headers: Cast iron per ASME requirements
  • Copper with integral formed external fins tubes
  • Aluminized steel main burners
  • Natural aspiration air supply
  • 115 V, 60 Hz, 1 Ph less than 12 A, 24 V transformer mounted and wired
  • Standard pump relay
  • Vent damper and wire harness
  • Flame rollout safety switch
  • 0 to 2000 ft altitude
  • Revision 2
  • ON/OFF Firing System
  • 1-phase