content loaded
MIRCOM D4120A Image 1

MIRCOM D4120A IN-LINE DUCT SMOKE DETECTOR

MFR Part #: D4120A
SKU #: 1082792
Brand: Mircom™
UPC: 400006112408
Mircom® D4120A Duct Smoke Detector, Photoelectric Sensor, 15 s Response, Surface Mounting

Mircom® Duct Smoke Detector, Humidity Rating: 0 to 95 %, Photoelectric Sensor, Air Duct Velocity: 100 to 4000 fpm, 65 mA Alarm Current, 270 uF Capacitance, 21 mA Maximum Standby Current, 20 to 29 V, Reset Voltage: 3 VDC, 0.6 s Reset, 15 s Response, Surface Mounting, -40 to 158 deg F

The InnovairFlex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 - 4000 fpm, temperatures of -4 to 158 deg F and a humidity range of 0 - 95% (non-condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The InnovairFlex housing provides ample wiring space, a 3/4 in conduit knockout and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor, D4S, simultaneously (i.e. supply and return side). As many as 50 InnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays, only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access test/reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings - cover tamper delay, number of sensors to be controlled and shut down on trouble option. Each power board has two LED's that can be used to indicate the status of connected sensors and a quick reference imprinted on the cover explains the LED status indications (standby, maintenance, trouble and alarm). The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories.

Product Details

Mircom® Duct Smoke Detector, Humidity Rating: 0 to 95 %, Photoelectric Sensor, Air Duct Velocity: 100 to 4000 fpm, 65 mA Alarm Current, 270 uF Capacitance, 21 mA Maximum Standby Current, 20 to 29 V, Reset Voltage: 3 VDC, 0.6 s Reset, 15 s Response, Surface Mounting, -40 to 158 deg F

The InnovairFlex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 - 4000 fpm, temperatures of -4 to 158 deg F and a humidity range of 0 - 95% (non-condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The InnovairFlex housing provides ample wiring space, a 3/4 in conduit knockout and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor, D4S, simultaneously (i.e. supply and return side). As many as 50 InnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays, only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access test/reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings - cover tamper delay, number of sensors to be controlled and shut down on trouble option. Each power board has two LED's that can be used to indicate the status of connected sensors and a quick reference imprinted on the cover explains the LED status indications (standby, maintenance, trouble and alarm). The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories.

Attributes

Air Duct Velocity100 to 4000 fpm
Alarm Current65 mA
Capacitance270 uF
Humidity Rating0 to 95 %
Maximum Standby Current21 mA
Mounting TypeSurface
Reset Time.6 s
Reset Voltage3 VDC
Response Time15 s
Sensor TypePhotoelectric
Temperature Rating-40 to 158 deg F
Voltage Rating20 to 29 V

Features

  • Photoelectric, integrated low flow technology
  • Air velocity rating from 100 - 4000 fpm (0.5 - 20.32 m/sec)
  • Versatile mounting options in square or rectangular configuration with modular construction
  • Plug-in sensor offers superb false alarm immunity and the latest sensor technology
  • Broad ranges for operating temperature (-4 to 158 deg F) and humidity (0 - 95% non-condensing)
  • Patented sampling tube installs from front or back of the detector with no tools required
  • Increased wiring space with a newly added 3/4 in conduit knockout
  • One easy access test/reset button and improved LED status
  • Patented interconnect feature for multi-fan shutdown
  • New high contrast terminal designations
  • Built-in short circuit protection from operator wiring errors
  • Field selectable settings for configuring the detector
  • (2) DPDT form-C relay contacts
  • 24 VAC/VDC or 120 VAC
  • Backward compatibility with existing Innovair products, including remote accessories