content loaded
MIRCOM MIX-2251APA Image 1

MIRCOM MIX-2251APA AP INTEL ULC PHOTOELECTRIC SMOKE DETECTOR

MFR Part #: MIX-2251APA
SKU #: 1244025
Brand: Mircom™
UPC: 400050366796
Mircom® MIX-2251APA Smoke Detector, 15 to 32 VDC Power Source, Photoelectric Sensor, LED Visual Indicator
FM Approved | UL S6295 | ULC S6295

Mircom® Smoke Detector, Photoelectronic Detection Method, 15 to 32 VDC, Smoke Alarm, LED Visual Indicator, 10 to 93% RH Non-Condensing Humidity Rating, Photoelectric Sensor, LED Display, 0 to 4000 fpm Air Duct Velocity, 6.5 mA Alarm Current, 300 uA Maximum Standby Current, 6.5 mA LED Current, 15 to 32 V, Ceiling Mounting, Plastic, 32 to 120 deg F, 2 in Height, Additional Information: 6.1 in Dia Installed in B210LP Base, 4.1 in Dia Installed in B501 Base

Mircom® low profile intelligent plug-in smoke detectors with integral communications provide features that surpass conventional detectors. Sensitivity is continuously monitored and reported to the panel where the desired detector sensitivity can be programmed. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level. Mircom® Advanced Protocol (AP) devices use a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. Mircom® Advanced Protocol uses a superior group polling method as well as an interrupt feature that provide for a faster response to an alarm condition. In addition, the Advanced Protocol allows for greater system capacity with support for up to 318 devices per SLC circuit. The AP devices are backwards compatible to operate in clip mode for legacy system applications. The MIX-2251AP provides a unique optical sensing chamber that senses smoke produced by a wide range of combustion sources.

Product Details

Mircom® Smoke Detector, Photoelectronic Detection Method, 15 to 32 VDC, Smoke Alarm, LED Visual Indicator, 10 to 93% RH Non-Condensing Humidity Rating, Photoelectric Sensor, LED Display, 0 to 4000 fpm Air Duct Velocity, 6.5 mA Alarm Current, 300 uA Maximum Standby Current, 6.5 mA LED Current, 15 to 32 V, Ceiling Mounting, Plastic, 32 to 120 deg F, 2 in Height, Additional Information: 6.1 in Dia Installed in B210LP Base, 4.1 in Dia Installed in B501 Base

Mircom® low profile intelligent plug-in smoke detectors with integral communications provide features that surpass conventional detectors. Sensitivity is continuously monitored and reported to the panel where the desired detector sensitivity can be programmed. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level. Mircom® Advanced Protocol (AP) devices use a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. Mircom® Advanced Protocol uses a superior group polling method as well as an interrupt feature that provide for a faster response to an alarm condition. In addition, the Advanced Protocol allows for greater system capacity with support for up to 318 devices per SLC circuit. The AP devices are backwards compatible to operate in clip mode for legacy system applications. The MIX-2251AP provides a unique optical sensing chamber that senses smoke produced by a wide range of combustion sources.

Attributes

Additional Information6.1 in Dia Installed in B210LP Base, 4.1 in Dia Installed in B501 Base
Air Duct Velocity0 to 4000 fpm
Alarm Current6.5 mA
Alarm TypeSmoke
Detection MethodPhotoelectronic
Display TypeLED
Height2 in
Humidity Rating10 to 93% RH Non-Condensing
LED Current6.5 mA
MaterialPlastic
Maximum Standby Current300 uA
Mounting TypeCeiling
Power Source15 to 32 VDC
Sensor TypePhotoelectric
Temperature Rating32 to 120 deg F
Visual Indicator TypeLED
Voltage Rating15 to 32 V

Features

  • Sleek, low profile design
  • Photoelectric technology
  • Dual LEDs indicate communications and activate steady when in alarm
  • Low profile base provides easy interchangeability
  • Low standby current
  • Rotary switches for direct dial entry of address, each unit can have address set for 01-159 for advanced protocol mode and 01-99 for clip mode
  • Magnetic test feature
  • Superior EMI protection
  • Sealed against dirt, insects and back pressure