content loaded
AXIOM SF100-2PRV-L-HP Image 1

AXIOM SF100-2PRV-L-HP LARGE CAPACITY HIGH PRESSURE WITH 2 PRESSURE REDUCING VALVES

MFR Part #: SF100-2PRV-L-HP
SKU #: 1163582
Brand: Axiom
UPC: 691846
AXIOM SF100-2PRV-L-HP Hydronic System Feeder, 25 to 85 psi, 208 L Capacity, 115 VAC
Storage/Mixing Tank with Cover, Pump Suction Hose with Inlet Strainer, Pressure Pump with Thermal Cut-Out, Integral Pressure Switch, Integral Check Valve, Cord and Plug, Pre-Charged Accumulator Tank with EPDM Diaphragm, Manual Diverter Valve, 25 to 85 psig Adjustable Pressure Regulating Valve with Pressure Gauge, Built-In Check Valve, Union Connection, 12 x 900 mm L Flexible Connection Hose with Check Valve and Low Level Pump Cut-Out
CAN/CSA C22.2 No. 68 Certified|cETLus Intertek Listed|UL73 9901055 Listed

AXIOM Hydronic System Feeder, 115 VAC, 60 Hz, 25 to 85 psi, 208 L Capacity, 53 in H x 33 in W

The SF100 contains everything required to feed and pressurize closed hydronic heating or cooling systems in a neat, simple package that is easy-to-install and operate. It is compatible with both water and water/glycol solutions.

Product Details

AXIOM Hydronic System Feeder, 115 VAC, 60 Hz, 25 to 85 psi, 208 L Capacity, 53 in H x 33 in W

The SF100 contains everything required to feed and pressurize closed hydronic heating or cooling systems in a neat, simple package that is easy-to-install and operate. It is compatible with both water and water/glycol solutions.

Attributes

Capacity: 208 L
Dimensions: 53 in H x 33 in W
Frequency Rating: 60 Hz
Pressure Rating: 25 to 85 psi
Voltage Rating: 115 VAC

Features

  • 208 L tank for storage and mixing
  • Plugs into any standard 115 VAC outlet
  • Fluid level switch shuts the pump-off if the storage tank level gets low
  • Accumulator tank prevents excessive pump cycling
  • No direct connection to potable water supply eliminates need for backflow prevention
  • Make-up fluid stored in the feeder tank can be pre-treated to meet appliance manufacturers specifications
  • Diverter valve for purging of air on initial start-up and manual agitation of solution
  • Prevents major floods - in the event of system rupture, only the contents of the tank will be pumped into the system
  • Dropping fluid level provides immediate notice that the system has developed a leak
  • Fluid drained for service can easily be put back into the system
  • Flexible connection hose with system check valve makes installation easy