content loaded
AXIOM SF100-2PRV-L Image 1

AXIOM SF100-2PRV-L LARGE CAPACITY WITH 2 PRESSURE REDUCING VALVES

MFR Part #: SF100-2PRV-L
SKU #: 1163580
Brand: Axiom
UPC: 691844
AXIOM SF100-2PRV-L Large Capacity Hydronic System Feeder, 5 to 55 psi, 383 L Capacity, 115 VAC
Storage/Mixing Tank with Cover, Pump Suction Hose with Inlet Strainer, Pressure Pump with Thermal Cut-Out, Integral Pressure Switch, Integral Check Valve, Cord and Plug, Pre-Charged Accumulator Tank with EPDM Diaphragm, Manual Diverter Valve for Purging Air and Agitating Contents of Storage Tank, 5 to 55 psig Adjustable Pressure Regulating Valve with Pressure Gauge, Built-In Check Valve, Union Connection, 12 x 900 mm L Flexible Connection Hose with Check Valve and Low Level Pump Cut-Out
CAN/CSA C22.2 No. 68 Certified|cETLus Intertek Listed|UL73 9901055 Listed

AXIOM Large Capacity Hydronic System Feeder, 115 VAC, 60 Hz, 5 to 55 psi, 383 L Capacity, 49 in H x 24 in W

The SF100-2PRV-L contains everything required to feed and pressurize 2-closed hydronic heating or cooling systems in a neat, simple package that is easy-to-install and operate. It is compatible with both water and water/glycol solutions.

Product Details

AXIOM Large Capacity Hydronic System Feeder, 115 VAC, 60 Hz, 5 to 55 psi, 383 L Capacity, 49 in H x 24 in W

The SF100-2PRV-L contains everything required to feed and pressurize 2-closed hydronic heating or cooling systems in a neat, simple package that is easy-to-install and operate. It is compatible with both water and water/glycol solutions.

Attributes

Capacity: 383 L
Dimensions: 49 in H x 24 in W
Frequency Rating: 60 Hz
Pressure Rating: 5 to 55 psi
Voltage Rating: 115 VAC

Features

  • 383 L tank for storage and mixing
  • (2) pressure reducing valve, pressure gauge, system connector hose and check valves to allow for independent pressure supply to isolated systems
  • Plugs into any standard 115 VAC outlet
  • Fluid level switch shuts the pump-off if the storage tank level gets low
  • Accumulator tank prevents excessive pump cycling
  • No direct connection to potable water supply eliminates need for backflow prevention
  • Make-up fluid stored in the feeder tank can be pre-treated to meet appliance manufacturers specifications
  • Prevents major floods - in the event of system rupture, only the contents of the tank will be pumped into the system
  • Dropping fluid level provides immediate notice that the system has developed a leak
  • Diverter valve for purging of air on initial start-up and manual agitation of solution
  • Fluid drained for service can easily be put back into the system
  • Flexible connection hose with system check valve makes installation easy