AXIOM SF100-D-P DUPLEX UNIT WITH ALTERNATING CONTROL PANEL

MFR Part #: SF100-D-P
SKU #: 1163586
Brand: Axiom
UPC: 691850
AXIOM SF100-D-P Packed Hydronic System Feeder With Alternating Control Panel, 5 to 55 psi, 208 L Capacity, 115 VAC
Storage/Mixing Tank with Cover, Pump Suction Hose with Inlet Strainer, (2) Pressure Pumps with Thermal Cut-Out, Pump Isolation Valves, (2) Integral Pressure Switches, Integral Check Valve, Cord and Plug, Pre-Charged Accumulator Tank with EPDM Diaphragm, Manual Diverter Valve, Adjustable 5 to 55 psig Pressure Regulating Valve with Pressure Gauge, Integral Replaceable Strainer, Built-In Check Valve, Union Connection, 12 x 900 mm L Flexible Connection Hose with Check Valve and Low Level Pump Cut-Out

AXIOM Packed Hydronic System Feeder With Alternating Control Panel, 115 VAC, 60 Hz, 1 ph Phase, 5 to 55 psi, 1.4 gpm Flow Rate, 208 L Capacity, 49 in H x 24 in W

The SF100-D-P contains everything required to feed and pressurize closed hydronic heating or cooling systems in a neat, simple package that is easy-to-install and operate. It is compatible with both water and water/glycol solutions.

Product Details

AXIOM Packed Hydronic System Feeder With Alternating Control Panel, 115 VAC, 60 Hz, 1 ph Phase, 5 to 55 psi, 1.4 gpm Flow Rate, 208 L Capacity, 49 in H x 24 in W

The SF100-D-P contains everything required to feed and pressurize closed hydronic heating or cooling systems in a neat, simple package that is easy-to-install and operate. It is compatible with both water and water/glycol solutions.

Attributes

Capacity: 208 L
Dimensions: 49 in H x 24 in W
Flow Rate: 1.4 gpm
Frequency Rating: 60 Hz
Phase: 1 ph
Pressure Rating: 5 to 55 psi
Voltage Rating: 115 VAC

Features

  • 208 L tank for storage and mixing
  • 2-pumps for seamless and reliable operation
  • Plugs into any standard 115 VAC outlet
  • Fluid level switch shuts the pump-off if the storage tank level gets low
  • Accumulator tank prevents excessive pump cycling
  • No direct connection to potable water supply eliminates need for backflow prevention
  • Make-up fluid stored in the feeder tank can be pre-treated to meet appliance manufacturers specifications
  • Prevents major floods - in the event of system rupture, only the contents of the tank will be pumped into the system
  • Dropping fluid level provides immediate notice that the system has developed a leak
  • Diverter valve for purging of air on initial start-up and manual agitation of solution
  • Fluid drained for service can easily be put back into the system
  • Flexible connection hose with system check valve makes installation easy