content loaded
WESTINGHOUSE BR130 Image 1

EATON BR130 PUSH-IN 30 AMP 1 POLE BREAKER

MFR Part #: BR130
SKU #: 0711060
Brand: EATON
UPC: 786676362207
EATON BR130 Type BR Circuit Breaker, 120/240 VAC, 30 A, 10 kAIC Interrupt, 1 Poles
10 years
Generation, Renewable Energy, Alternative Energy, Conventional Energy, Conventional Energy, Datacenters, CI and Hyper Converged IT Space, Marine Vessels and Equipment
CSA Certified | NEMA Approved | UL 489 | Federal Specification W-C-375 | HACR Rated

EATON Circuit Breaker, Type BR, 120/240 VAC, 30 A, 10 kAIC Interrupt, 1 Pole, 1 ph, Plug-On, 14 to 4 AWG Copper/Aluminum Wire, NEMA 1/3R/4X, Plug-On Mount, 60 to 75 deg C, 3 in L x 1 in W x 3 in H

A branch feeder-type arc fault circuit interrupter is a device intended to mitigate high current arcing faults in the complete circuit, including connected cords. high current arcing faults can occur from line to neutral or line to ground. these arcing faults are in parallel with the load and produce the most energy of all arcing faults. the branch feeder type AFCI is required in the 1999 and 2002 national electrical code the combination type AFCI is required in the 2005, 2008 and 2011 national electrical code.

Product Details

EATON Circuit Breaker, Type BR, 120/240 VAC, 30 A, 10 kAIC Interrupt, 1 Pole, 1 ph, Plug-On, 14 to 4 AWG Copper/Aluminum Wire, NEMA 1/3R/4X, Plug-On Mount, 60 to 75 deg C, 3 in L x 1 in W x 3 in H

A branch feeder-type arc fault circuit interrupter is a device intended to mitigate high current arcing faults in the complete circuit, including connected cords. high current arcing faults can occur from line to neutral or line to ground. these arcing faults are in parallel with the load and produce the most energy of all arcing faults. the branch feeder type AFCI is required in the 1999 and 2002 national electrical code the combination type AFCI is required in the 2005, 2008 and 2011 national electrical code.

Attributes

Amperage Rating: 30 A
Country Of Origin: Mexico
Mounting Type: Plug-On
Number of Poles: 1
Connection Type: Plug-On
Dimensions: 3 in L x 1 in W x 3 in H
Enclosure Type: NEMA 1/3R/4X
Interrupt Rating: 10 kAIC
Phase: 1
Temperature Rating: 60 to 75 deg C
Type: Type BR
Voltage Rating: 120/240 VAC
Wire Size: 14 to 4 AWG Copper/Aluminum

Features

  • Common trip requires (1) 1 in space
  • All BR circuit breakers have rejection tab feature
  • Units feature a quick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip-free handle design
  • For 1-pole circuit breakers carry listing for HACR application