FUSES L60030C-1SQ Image 1

30A 600V 1P SCREW TERM CLASS CC FUSE HLDR FUSES L60030C-1SQ

MFR Part #: L60030C-1SQ
SKU #: 1002328
Brand: Littelfuse®
UPC: 079458070194
Littelfuse® POWR-GARD® L60030C-1SQ Fuse Block, 600 VAC/VDC, 30 A, Class: CC, 14 to 10 AWG Wire, 1 Pole
UL File No. E14721|CSA File No. LR7316|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer.

Littelfuse® POWR-GARD® Fuse Block, Series: L600C, 600 VAC/VDC, 30 A, 1 Pole, Class: CC, Screw Connection, 14 to 10 AWG Wire, DIN Rail Mounting, 1-1/2 in Fuse Length, 13/32 in Diameter Fuse, 125 deg C, For Use With: CCMR, KLDR and KLKR Series Fuse, Thermoplastic, 3 in L x 0.783 in W x 1.25 in H Dimensions

Space-saving 600 V, 30 A molded case fuse blocks with side barriers for isolation. Class CC blocks and midget blocks are identical except class CC blocks incorporate a rejection feature to assure Proper fusing. Safety : rejection feature class CC fuse blocks have a rejection feature which prevents the insertion of fuses with lower interrupting rating or voltage ratings. Class CC fuses are rated 600 V and have an interrupting rating of 200000 A. Midget fuse voltage ratings vary and their interrupting rating may be as low as 10000 A. Note that class CC fuses may be used in midget fuse blocks, but midget fuses cannot be used in class CC blocks. Long Life: high-strength materials class CC and midget fuse blocks are molded of high-strength, high temperature material to minimize block breakage during handling and installation, as well as damage due to heat. Reduced resistance, less heat high conductivity, one piece copper alloy fuse clips have lower resistance than traditional two piece brass or phosphor bronze fuse clips minimizes heat rise and watts loss within the fuse block. Reduced inVentory: Gangable interlocking fuse blocks allow ganging to produce a fuse block with any number of poles. Flexible terminal arrangements 30 A class CC and midget fuse blocks are available with type C box lug, type SQ screw or type PQ pressure plate terminals. Type SQ terminals have binding head screws, while type PQ terminals have captive pressure plates. Both terminal types can accommodate side or top mounted quick connect terminals. This flexibility allows the accommodation of most needs and reduces part inVentory requirements.

Product Details

Littelfuse® POWR-GARD® Fuse Block, Series: L600C, 600 VAC/VDC, 30 A, 1 Pole, Class: CC, Screw Connection, 14 to 10 AWG Wire, DIN Rail Mounting, 1-1/2 in Fuse Length, 13/32 in Diameter Fuse, 125 deg C, For Use With: CCMR, KLDR and KLKR Series Fuse, Thermoplastic, 3 in L x 0.783 in W x 1.25 in H Dimensions

Space-saving 600 V, 30 A molded case fuse blocks with side barriers for isolation. Class CC blocks and midget blocks are identical except class CC blocks incorporate a rejection feature to assure Proper fusing. Safety : rejection feature class CC fuse blocks have a rejection feature which prevents the insertion of fuses with lower interrupting rating or voltage ratings. Class CC fuses are rated 600 V and have an interrupting rating of 200000 A. Midget fuse voltage ratings vary and their interrupting rating may be as low as 10000 A. Note that class CC fuses may be used in midget fuse blocks, but midget fuses cannot be used in class CC blocks. Long Life: high-strength materials class CC and midget fuse blocks are molded of high-strength, high temperature material to minimize block breakage during handling and installation, as well as damage due to heat. Reduced resistance, less heat high conductivity, one piece copper alloy fuse clips have lower resistance than traditional two piece brass or phosphor bronze fuse clips minimizes heat rise and watts loss within the fuse block. Reduced inVentory: Gangable interlocking fuse blocks allow ganging to produce a fuse block with any number of poles. Flexible terminal arrangements 30 A class CC and midget fuse blocks are available with type C box lug, type SQ screw or type PQ pressure plate terminals. Type SQ terminals have binding head screws, while type PQ terminals have captive pressure plates. Both terminal types can accommodate side or top mounted quick connect terminals. This flexibility allows the accommodation of most needs and reduces part inVentory requirements.

Attributes

Amperage Rating30 A
ClassCC
Connection TypeScrew
Country Of OriginCN
Dimensions3 in L x 0.783 in W x 1.25 in H
Fuse Diameter13/32 in
Fuse Length1-1/2 in
MaterialThermoplastic
Mounting TypeDIN Rail
Number of Poles1
SeriesL600C
Suitable For Use WithCCMR, KLDR and KLKR Series Fuse
Temperature Rating125 deg C
Voltage Rating600 VAC/VDC
Wire Size14 to 10 AWG

Features

  • Space saving design
  • Universal mounting holes for easy replacement
  • Indication offered on CD blocks
  • Rejection feature that prevents the insertion of fuses with lower interrupting rating or voltage ratings
  • Clip design reduces resistance and heat
  • 1200 VAC minimum dielectric strength
  • Covers available for all amperages to enhance safety
  • Copper box lug
  • Zinc plated steel screw and captive pressure plate
  • Tin plated copper alloy clip/terminals
  • Lead-free
  • 2.3 N-m torque
  • Pressure plate with quick connect terminal
  • Cu solid/stranded wire
  • One hand release from DIN rail optional