SALUS AKL06PRF 6 ZONE WIRELESS PUMP CONTROL

MFR Part #: AKL06PRF
SKU #: 1243537
Brand: Salus
UPC: 817989023049
SALUS® AKL06PRF Wireless Pump Relay Controller, 6-Zone, 20 A, ABS
5 Year Limited

SALUS® Wireless Pump Relay Controller, 20 A, 120 VAC, 1/6 hp, 6 Zones, ABS, 32 to 110 deg F, 3.15 x 11 x 9.25 in

The SALUS® AKL06PRF wireless pump relay controller connects up to six zones providing heat to each circuit based on signals from SALUS® wireless thermostats. Optional zone 1 priority may be used in conjunction with a wired domestic hot water storage tank thermostat or other critical zone to give demand precedence to this zone above others. Optional pump exercising prevents the circulators from seizing during long periods of inactivity. Pump purge is another optional feature that improves the system efficiency by continuing to run the priority pump for 2 minutes after the zone 1 demand is satisfied. The unique SALUS® wireless system allows remote monitoring via internet connection.

Product Details

SALUS® Wireless Pump Relay Controller, 20 A, 120 VAC, 1/6 hp, 6 Zones, ABS, 32 to 110 deg F, 3.15 x 11 x 9.25 in

The SALUS® AKL06PRF wireless pump relay controller connects up to six zones providing heat to each circuit based on signals from SALUS® wireless thermostats. Optional zone 1 priority may be used in conjunction with a wired domestic hot water storage tank thermostat or other critical zone to give demand precedence to this zone above others. Optional pump exercising prevents the circulators from seizing during long periods of inactivity. Pump purge is another optional feature that improves the system efficiency by continuing to run the priority pump for 2 minutes after the zone 1 demand is satisfied. The unique SALUS® wireless system allows remote monitoring via internet connection.

Attributes

Amperage Rating20 A
Dimensions3.15 x 11 x 9.25 in
Temperature Rating32 to 110 deg F
MaterialABS
Number of Zones6
Power Supply1/6 hp
Voltage Rating120 VAC

Features

  • Primary pump control
  • Priority zone support (domestic hot water)
  • Purge priority pump continues to run for 2 mins after end of priority call
  • Exercise pumps turn ON for 30 s after 72 hr of inactivity
  • Thermostat grouping
  • ZC/ZR boiler enable support
  • Wireless boiler XX support with a zigbee receiver (AX10RF)
  • XX and AUX normally open contacts support
  • Master/slave function for up to five units (1 master/4 slaves)
  • External antenna for sheltered locations
  • LED indicators for zones and priority status