content loaded
MERSEN TRS10R Image 1

MERSEN TRS10R 600V 10A 5X13/16 TIME DELAY FUSE SMART

MFR Part #: TRS10R
SKU #: 1086378
Brand: Mersen
UPC: 782001748807
Mersen Tri-Onic® TRS10R Current Limiting Low Voltage Time Delay Fuse, 10 A, 600 VAC/VDC, 200/20 kA Interrupt, RK5 Class, Cylindrical Body
Motor Circuits, Mains, Feeders, Branch Circuits, Transformers, Service Entrance Equipment and General Purpose Equipment Applications
UL 248-12 File No. E2137 | CSA C22.2 File No.248.12

Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TRS-R, Non-Indicating, Rejection, 10 A, 600 VAC/VDC, 200/20 kA Interrupt, Class: RK5, Ferrule Terminal, Clip Mounting, Cylindrical Body, Dual Element, Polyester, 13/16 in Dia x 5 in L Body

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Product Details

Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TRS-R, Non-Indicating, Rejection, 10 A, 600 VAC/VDC, 200/20 kA Interrupt, Class: RK5, Ferrule Terminal, Clip Mounting, Cylindrical Body, Dual Element, Polyester, 13/16 in Dia x 5 in L Body

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Attributes

Amperage Rating: 10 A
Body Size: 13/16 in Dia x 5 in L
Body Type: Cylindrical
Class: RK5
Country Of Origin: Mexico
Element: Dual
Indicating/Non-Indicating: Non-Indicating
Interrupt Rating: 200/20 kA
Material: Polyester
Mounting Type: Clip
Rejection/Non-Rejection: Rejection
Series: TRS-R
Terminal Type: Ferrule
Type: Current Limiting Low Voltage
Voltage Rating: 600 VAC/VDC

Features

  • Time delay for motor start-ups and transformer inrush currents without nuisance opening
  • Current limiting for low peak let-thru current
  • Rejection style design prevents replacement errors
  • Easy-to-read label for quick brand recognition and replacement
  • Metal embossed date and catalog number for traceability and lasting identification
  • Fiberglass body provides dimensional stability in harsh industrial settings
  • High grade silica filler ensures fast arc quenching and high current limitation
  • North American power fuses
  • Copper, tin-plated copper contact