MERSEN AJT100 600V 100A CLASS J TIME DELAY FUSE

MFR Part #: AJT100
SKU #: 1086133
Brand: Mersen
UPC: 0782001962487
Mersen AMP-TRAP® 2000 SmartSpot® AJT100 Current Limiting Low Voltage North American Time Delay Power Fuse, 100 A, 600 VAC, 200 kA Interrupt, J Class, Cylindrical Body
Motor Circuits, Mains, Feeders, Branch Circuits, Lighting, Heaters, Transformers, Control Panels, Circuit Breaker Back-Up, Bus Duct and Load Centers Applications
CSA C22.2 No. 248.8 | DC Listed | IEC 269-2-1 | RoHS Compliant | UL 248 | UL 248-8 File No. E2137

Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: AJT, Indicating, Rejection, 100 A, 600 VAC, 200 kA Interrupt, Class: J, Blade Terminal, Clip Mounting, Cylindrical Body, Dual Element, Fiberglass, 1-1/16 in Dia x 4-5/8 in L Body

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Product Details

Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: AJT, Indicating, Rejection, 100 A, 600 VAC, 200 kA Interrupt, Class: J, Blade Terminal, Clip Mounting, Cylindrical Body, Dual Element, Fiberglass, 1-1/16 in Dia x 4-5/8 in L Body

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Attributes

Amperage Rating: 100 A
Body Size: 1-1/16 in Dia x 4-5/8 in L
Body Type: Cylindrical
Class: J
Country Of Origin: Mexico
Element: Dual
Indicating/Non-Indicating: Indicating
Interrupt Rating: 200 kA
Material: Fiberglass
Mounting Type: Clip
Rejection/Non-Rejection: Rejection
Series: AJT
Terminal Type: Blade
Type: Current Limiting Low Voltage North American Time Delay
Voltage Rating: 600 VAC

Features

  • Solid state SmartSpot® indicator
  • Time delay for motor starting and transformer inrush
  • 300 kA interrupting rating, self certified (UL witnessed)
  • Extremely current limiting for low peak let-thru current
  • Most current limiting UL class fuse
  • Small footprint requires less mounting space and allows smaller, more economical fuse blocks
  • Easy 2-to-1 selectivity for prevention of nuisance shutdowns
  • Unique class J dimensions prevent replacement errors
  • High visibility orange label gives instant recognition
  • Metal embossed date and catalog number for traceability and lasting identification
  • Fiberglass body provides dimensional stability in harsh industrial settings
  • High grade silica filler ensures fast arc quenching
  • Tin-plated copper, silver-plated copper contact