MERSEN ATDR30 Image 1

MERSEN ATDR30 600V 30A CC TIME DELAY FUSE

MFR Part #: ATDR30
SKU #: 1086162
Brand: Mersen
UPC: 0782001908706
Mersen AMP-TRAP® 2000 SmartSpot® ATDR30 Current Limiting North American Time Delay Power Fuse, 30 A, 600 VAC, 200 kA Interrupt, CC Class, Cylindrical Body
Small Motor, Contactor, Branch Circuit Protection, Lighting, Heater, General Loads, Conventional Energy, Renewable Energy and Alternative Energy Generation, Datacenters, IT Space - CI, Hyper Converged, Marine Vessels and Equipment Applications
CSA C22.2 No. 248.4 | DC Listed | UL 248 | UL 248-4 File No. E2137

Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting North American Time Delay, Series: ATDR, Non-Indicating, Rejection, 30 A, 600 VAC, 200 kA Interrupt, Class: CC, Ferrule Terminal, Clip Mounting, Cylindrical Body, Dual Element, Fiberglass, 13/32 in Dia x 1-1/2 in L Body

Amp-Trap 2000 time-delay ATDR small-dimension fuses provide IEC Type 2 "no damage" protection to your facility's increasingly sensitive branch circuit components and small motors - minimizing the risk of fault-related damage. ATDR Class CC fuses deliver the best time-delay characteristics in their class with excellent cycling ability for small motor loads.

Product Details

Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting North American Time Delay, Series: ATDR, Non-Indicating, Rejection, 30 A, 600 VAC, 200 kA Interrupt, Class: CC, Ferrule Terminal, Clip Mounting, Cylindrical Body, Dual Element, Fiberglass, 13/32 in Dia x 1-1/2 in L Body

Amp-Trap 2000 time-delay ATDR small-dimension fuses provide IEC Type 2 "no damage" protection to your facility's increasingly sensitive branch circuit components and small motors - minimizing the risk of fault-related damage. ATDR Class CC fuses deliver the best time-delay characteristics in their class with excellent cycling ability for small motor loads.

Attributes

Amperage Rating: 30 A
Body Size: 13/32 in Dia x 1-1/2 in L
Body Type: Cylindrical
Class: CC
Country Of Origin: Mexico
Element: Dual
Indicating/Non-Indicating: Non-Indicating
Interrupt Rating: 200 kA
Material: Fiberglass
Mounting Type: Clip
Rejection/Non-Rejection: Rejection
Series: ATDR
Terminal Type: Ferrule
Type: Current Limiting North American Time Delay
Voltage Rating: 600 VAC

Features

  • Time delay for motor starting inrush currents without nuisance opening
  • Highly current limiting for low peak let through current
  • Improved cycling ability for frequent motor starts/stops without nuisance fuse opening
  • Rejection style design prevents replacement errors (when used with recommended fuse blocks)
  • High visibility orange label ensures instant brand recognition, simplifies replacement
  • Metal embossed date and catalog number for traceability and lasting identification
  • Fiberglass body provides dimensional stability in harsh industrial settings
  • High grade silica filler ensures fast arc quenching and optimum current limitation
  • Tin-plated copper contact