ABB AF40-30-00-11 Image 1

ABB AF40-30-00-11 CONTACTOR 3 POLE 40HP 600VAC

MFR Part #: AF40-30-00-11
SKU #: 1111966
Brand: ABB
UPC: 888614075016
ABB AF40-30-00-11 AF Series IEC Contactor, 24/60 VAC V Coil, 40 A, 3NO Contact, 3 Poles
For controlling 3-phase motors, non-inductive or slightly inductive load applications

ABB, AF40-30-00-11, IEC Contactor, Series: AF Series, 24/60 VAC Coil, 40 A Maximum Load Current, 3 Pole, 50/60 Hz Frequency, 22 kW Wattage, 3NO Contact Configuration, Screw Terminal, IP10 Enclosure, 3600 Cycles Operating Cycles, -40 to 70 deg C Operating, DIN Rail Mounting, 125-1/2 mm H x 55 mm W x 111 mm D Dimensions

AF40 contactors are used for controlling power circuits up to 690 VAC and 220 VDC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF contactors include an electronic coil interface accepting a wide control voltage Uc min, Uc max. Only four coils cover control voltages between 24 to 500 VAC 50/60 Hz or 20 to 500 VAC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF series 1-stack 3-pole contactors are of the block type design. Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. Mirror contacts compliant with Annex F of IEC 60947-4-1) - control circuit: AC or DC operated.

Product Details

ABB, AF40-30-00-11, IEC Contactor, Series: AF Series, 24/60 VAC Coil, 40 A Maximum Load Current, 3 Pole, 50/60 Hz Frequency, 22 kW Wattage, 3NO Contact Configuration, Screw Terminal, IP10 Enclosure, 3600 Cycles Operating Cycles, -40 to 70 deg C Operating, DIN Rail Mounting, 125-1/2 mm H x 55 mm W x 111 mm D Dimensions

AF40 contactors are used for controlling power circuits up to 690 VAC and 220 VDC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF contactors include an electronic coil interface accepting a wide control voltage Uc min, Uc max. Only four coils cover control voltages between 24 to 500 VAC 50/60 Hz or 20 to 500 VAC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF series 1-stack 3-pole contactors are of the block type design. Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. Mirror contacts compliant with Annex F of IEC 60947-4-1) - control circuit: AC or DC operated.

Attributes

Coil Voltage24/60 VAC
Contact Configuration3NO
Dimensions125-1/2 mm H x 55 mm W x 111 mm D
Enclosure TypeIP10
Frequency Rating50/60 Hz
Maximum Load Current40 A
Mounting TypeDIN Rail
Number of Poles3
Operating Cycles3600 Cycles
Operating Temperature-40 to 70 deg C
SeriesAF Series
Terminal TypeScrew
Wattage22 kW

Features

  • 3NO-0NC (main), 0NO-0NC (auxiliary) contact configuration
  • 22 kW at 415/440/500/690 VAC, 18.5 kW at 380/400 VAC, 11 kW at 220/230/ 240 VAC wattage
  • 24/60 VAC, 20/60 VDC coil voltage rating