content loaded
ABB AF40-30-00-13 Image 1

ABB AF40-30-00-13 CONTACTOR 3 POLE 40HP 600VAC

MFR Part #: AF40-30-00-13
SKU #: 1111967
Brand: ABB
UPC: 888614006836
ABB AF40-30-00-13 IEC Contactor, 100 VAC, 250 VDC V Coil, 60 A, 3NO Contact, 3 Poles
Surge Suppression
For controlling single and three phase motors and switching power circuits
RoHS Compliant | cUL Listed | UL 508 | CSA C22.2 No. 14 | IEC Standard | EN 60947-4-1/60947-4-1A/60947-4-1-07 | CE Certified | EAC Certified

ABB IEC Contactor, Series: AF40, 100 VAC, 250 VDC Coil, 60 A Maximum Load Current, 30 hp Coil, 3 Pole, 50/60 Hz Frequency, 22 kW Wattage, Non-Reversing Contact, 3NO Contact Configuration, 40 Frame Size, Screw Terminal, IP10 Enclosure, -60 to 80 deg C Operating, DIN Rail Mounting, 125.5 mm H x 55 mm W x 111 mm D Dimensions

AF series contactors are provided in either three or four power pole configurations with a variety of accessories including auxiliary contacts, close coupling adaptors, interlocks and busbars.

Product Details

ABB IEC Contactor, Series: AF40, 100 VAC, 250 VDC Coil, 60 A Maximum Load Current, 30 hp Coil, 3 Pole, 50/60 Hz Frequency, 22 kW Wattage, Non-Reversing Contact, 3NO Contact Configuration, 40 Frame Size, Screw Terminal, IP10 Enclosure, -60 to 80 deg C Operating, DIN Rail Mounting, 125.5 mm H x 55 mm W x 111 mm D Dimensions

AF series contactors are provided in either three or four power pole configurations with a variety of accessories including auxiliary contacts, close coupling adaptors, interlocks and busbars.

Attributes

Coil Power Rating: 30 hp
Coil Voltage: 100 VAC, 250 VDC
Contact Configuration: 3NO
Contact Type: Non-Reversing
Country Of Origin: France
Dimensions: 125.5 mm H x 55 mm W x 111 mm D
Enclosure Type: IP10
Frequency Rating: 50/60 Hz
Maximum Load Current: 60 A
Mounting Type: DIN Rail
Number of Poles: 3
Operating Temperature: -60 to 80 deg C
Series: AF40
Size: 40 Frame
Terminal Type: Screw
Wattage: 22 kW

Features

  • AF contactors can manage large control voltage variations one coil can be used for different control voltages used worldwide without any coil change
  • AF series contactor coils are designed to utilize both AC (50/60 Hz) and DC control circuit inputs ranging from 24 to 500 VAC
  • Main poles and auxiliary contact blocks 3 main poles, 1 built-in auxiliary contact, front and side mounted add-on auxiliary contact blocks (mechanically linked auxiliary contacts compliant with Annex L of IEC 60947-5-1
  • 6 kV rated impulse withstand voltage
  • 600/690 VAC rated insulation voltage
  • 3000 m maximum operating altitude permissible
  • 3 hp at 120 VAC/7-1/2 hp at 240 VAC 1-phase and 10 hp at 200/208 VAC/15 hp at 220/240 VAC/30 hp at 440/480 VAC/45 hp at 550/600 VAC 3-phase power rating