content loaded
ABB MS165-54 Image 1

ABB MS165-54 MAN MOTOR STARTER SHORT CIRC O/LOAD PHASE FAIL

MFR Part #: MS165-54
SKU #: 1219779
Brand: ABB
UPC: 888614384224
ABB MS165-54 Manual Motor Starter, ON/OFF/Trip Action, 3 Poles, IP10/IP20 Enclosure

ABB Manual Motor Starter, Series: MS165, 690 VAC, 250 VDC, 54 A, 50/60 Hz Frequency, 22 kW Wattage, 3 hp, 10 hp, 15 hp, 20 hp, 40 hp, 50 hp Motor, 3 Pole, Setting: 40 to 54 A, 1/3 ph, Screw Connection, ON/OFF/Trip Action, 34/46.2/48.3/50/52/54 A Full Load, IP10/IP20 Enclosure, 25000/50000 Cycles Operating Cycles, -25 to 60 deg C Operating, 5.62 in H x 2.17 in W Dimensions

Manual motor starters (also known as motor protection circuit breakers or manual motor protectors) are electromechanical protection devices for the main circuit mainly used to switch motors manually On/Off and protect them fuseless against short-circuits, overloads and phase failures. Fuseless protection with a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off the motor within milliseconds. Fuseless starter combinations are setup together with contactors.

Product Details

ABB Manual Motor Starter, Series: MS165, 690 VAC, 250 VDC, 54 A, 50/60 Hz Frequency, 22 kW Wattage, 3 hp, 10 hp, 15 hp, 20 hp, 40 hp, 50 hp Motor, 3 Pole, Setting: 40 to 54 A, 1/3 ph, Screw Connection, ON/OFF/Trip Action, 34/46.2/48.3/50/52/54 A Full Load, IP10/IP20 Enclosure, 25000/50000 Cycles Operating Cycles, -25 to 60 deg C Operating, 5.62 in H x 2.17 in W Dimensions

Manual motor starters (also known as motor protection circuit breakers or manual motor protectors) are electromechanical protection devices for the main circuit mainly used to switch motors manually On/Off and protect them fuseless against short-circuits, overloads and phase failures. Fuseless protection with a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off the motor within milliseconds. Fuseless starter combinations are setup together with contactors.

Attributes

ActionON/OFF/Trip
Amperage Rating54 A
Connection TypeScrew
Dimensions5.62 in H x 2.17 in W
Enclosure TypeIP10/IP20
Frequency Rating50/60 Hz
Full Load Current34/46.2/48.3/50/52/54 A
Motor Power3 hp, 10 hp, 15 hp, 20 hp, 40 hp, 50 hp
Number of Poles3
Operating Cycles25000/50000 Cycles
Operating Temperature-25 to 60 deg C
Phase1/3
SeriesMS165
Setting40 to 54 A
Voltage Rating690 VAC/250 VDC
Wattage22 kW

Features

  • Overload protection - trip class 10
  • Phase loss sensitivity
  • Disconnect function
  • Temperature compensation from -25 to 60 deg C
  • Adjustable and sealable current setting for overload protection
  • Suitable for three and single-phase applications
  • Trip-free mechanism
  • Status indication for short-circuit trip
  • Clear switch position indication On-Off/trip
  • Lockable handle
  • 50000 mechanical, 25000 electrical cycles
  • 3 hp at 120 VAC 1 phase, 10 hp at 220 to 240 VAC 1 phase, 15 hp at 200 VAC 3 phase, 208 VAC 3 phase, 20 hp at 220 to 240 VAC 3 phase, 40 hp at 440 to 480 VAC 3 phase, 50 hp at 550 to 600 VAC 3 phase horsepower rating
  • 34 A at 120 VAC 1 phase, 50 A at 220 to 240 VAC 1 phase, 48.3 A at 200 VAC 3 phase, 46.2 A at 208 VAC 3 phase, 54 A at 220 to 240 VAC 3 phase, 52 A at 440 to 480 VAC 3 phase, 550 to 600 VAC 3 phase full load current rating