SIEMENS BF250A Image 1

BOLT-ON GFCI BREAKER 2P 50A 10KA SIEMENS BF250A

MFR Part #: BF250A
SKU #: 1133525
Brand: Siemens
UPC: 887621215453
Siemens BF250A Circuit Breaker, 120/240 VAC, 50 A, 10 kA Interrupt, 2 -Pole, Thermal Magnetic Trip
For spas, hot tubs, kitchens, bathrooms and residential use
HACR Rated | SWD Rated | UL 943

Siemens Circuit Breaker, 50 A, 120/240 VAC, 10 kA Interrupt Rating, 2 Poles, 1 ph Phase, Bolt-On Connection, BLF Frame, Thermal Magnetic Trip, 5 mA Trip, Load Side Lug Terminal, 8 to 6 AWG, 8 to 4 AWG Wire, 2 in Width, 3 in Length, 2.78 in Height

Ground fault circuit interrupters (GFCI) are an effective means of preventing severe electrical shock or electrocution from ground faults. To protect equipment from damaging ground faults, Siemens GFCIs monitor the difference in current between the hot and neutral conductors. If the electricity going to an outlet equals the current coming back from the outlet, the GFCI is dormant. If the electricity going to an outlet is greater than 5 mA than the current coming back from the outlet, the GFCI will open the circuit to stop of flow of electricity. With the extension of the National Electrical Code 2020 to protect more areas of the home, Siemens has expanded the GFCI product line to include 25, 35 and 45 A ratings, continuing to provide complete home safety for our customers. The NEC 2020 Article 210.8(F) extends GFCI protection to circuits feeding HVAC units and other modern-life applications.

Product Details

Siemens Circuit Breaker, 50 A, 120/240 VAC, 10 kA Interrupt Rating, 2 Poles, 1 ph Phase, Bolt-On Connection, BLF Frame, Thermal Magnetic Trip, 5 mA Trip, Load Side Lug Terminal, 8 to 6 AWG, 8 to 4 AWG Wire, 2 in Width, 3 in Length, 2.78 in Height

Ground fault circuit interrupters (GFCI) are an effective means of preventing severe electrical shock or electrocution from ground faults. To protect equipment from damaging ground faults, Siemens GFCIs monitor the difference in current between the hot and neutral conductors. If the electricity going to an outlet equals the current coming back from the outlet, the GFCI is dormant. If the electricity going to an outlet is greater than 5 mA than the current coming back from the outlet, the GFCI will open the circuit to stop of flow of electricity. With the extension of the National Electrical Code 2020 to protect more areas of the home, Siemens has expanded the GFCI product line to include 25, 35 and 45 A ratings, continuing to provide complete home safety for our customers. The NEC 2020 Article 210.8(F) extends GFCI protection to circuits feeding HVAC units and other modern-life applications.

Attributes

Amperage Rating50 A
Connection TypeBolt-On
Number of Poles2
Frame TypeBLF
Height2.78 in
Interrupt Rating10 kA
Length3 in
Phase1 ph
Terminal TypeLoad Side Lug
Trip Range5 mA
Trip TypeThermal Magnetic
Voltage Rating120/240 VAC
Width2 in
Wire Size8 to 6 AWG, 8 to 4 AWG

Features

  • Includes self-test as required by UL 943 as an added safety feature
  • Resists false tripping (shielded to prevent RF interference)
  • Standard 1 in per pole format with plug-in design
  • Provides Class A GFCI protection