content loaded
LEVITON ODC05-MDW Image 1

LEVITON ODC05-MDW PROVOLT 120V 500SQFT CEILING MOUNT OCCUPENCY SENSOR WITH INTEGRATED PHOTOCELL WHITE

MFR Part #: ODC05-MDW
SKU #: 1268881
Brand: Leviton®
UPC: 07847753997
Leviton® Provolt™ ODC05-MDW Occupancy Sensor, 120 to 277 VAC, PIR/Ultrasonic Sensor, 500 sq-ft Coverage, Ceiling Mount
5 Years Limited
Open and Closed Loop Photocell
Commercial Applications
RoHS Compliant | ASHRAE 90.1 | CEC Title 20/24 | UL 924 | UL 773A | NOM Certified | NY LLC48

Leviton® Provolt™ Occupancy Sensor, 120 to 277 VAC, 60 to 30 mA, PIR/Ultrasonic Sensor, 500 sq-ft Coverage, 30 s to 30 min Time Delay, 50/60 Hz Response, Wired Connection, Automatic On/Off/Manual On Control Output, Ceiling Mounting, 32 to 104 deg F, White, 4.81 in Dia x 2.39 in H Dimensions

The Leviton® Provolt™ series combine line voltage occupancy sensors and photocells into a self-contained unit. The integrated design alleviates the need for separate power pack and occupancy sensor wiring making it a low cost, efficient energy solution for new construction and retrofits.

Product Details

Leviton® Provolt™ Occupancy Sensor, 120 to 277 VAC, 60 to 30 mA, PIR/Ultrasonic Sensor, 500 sq-ft Coverage, 30 s to 30 min Time Delay, 50/60 Hz Response, Wired Connection, Automatic On/Off/Manual On Control Output, Ceiling Mounting, 32 to 104 deg F, White, 4.81 in Dia x 2.39 in H Dimensions

The Leviton® Provolt™ series combine line voltage occupancy sensors and photocells into a self-contained unit. The integrated design alleviates the need for separate power pack and occupancy sensor wiring making it a low cost, efficient energy solution for new construction and retrofits.

Attributes

Amperage Rating: 60 to 30 mA
Color: White
Connection Type: Wired
Control Output: Automatic On/Off/Manual On
Country Of Origin: China
Coverage: 500 sq-ft
Dimensions: 4.81 in Dia x 2.39 in H
Mounting Type: Ceiling
Response Frequency: 50/60 Hz
Sensor Type: PIR/Ultrasonic
Temperature Rating: 32 to 104 deg F
Time Delay: 30 s to 30 min
Voltage Rating: 120 to 277 VAC

Features

  • Sensors combine both PIR and U/S technology for unrivaled performance and reliability
  • Sensors use PIR technology to initially turn lights on and use U/S technology to keep the lights on
  • Exclusive false detection software assures lights are on only when needed
  • Auto adapting time delay and sensitivity are continually adjusted to occupancy pattern of use
  • Delayed off timer the sensor will turn lights off if no motion is detected after a specified time
  • Exclusive walk through feature provides increased energy savings by not leaving the lights on for an extended period after only momentary occupancy
  • False detection timer (M/T) the PIR scans for movement and shuts lights off after 31 min preventing false triggers from HVAC systems
  • Time delay and saved settings are protected during power outages and will return to the last known state
  • Industry exclusive self-configuring local manual switch input momentary or maintained switches are supported
  • Presentation mode feature for slide or film presentations allows push buttons to turn lights off and keep them off while the room is occupied
  • Test mode for simplified commissioning
  • Manual switch and emergency override are class 1 and 2 circuits, class 2 circuits provided for flexibility
  • Industry exclusive fail safe circuitry in the event of product failure, return to closed feature causes the relay to default on which eliminates life safety concerns
  • Industry exclusive HIS (High inrush Stability) technology designed to handle today's high inrush electronic ballast loads and offer unmatched durability and service
  • Robust and reliable mechanically held 10 a latching relay provides dependability and robust performance for all load types and provides energy savings over electronically held relays
  • Lenses are easily replaceable and color coded blue (high density) and red (mid range) for contractors and end users to easily identify lenses from the ground
  • Red visual LED indicator blinks when infrared is detecting motion and during photocell manual calibration, solid during device malfunction
  • Green visual LED indicator blinks when U/S is detected, solid during auto calibration
  • Yellow visual LED indicator blinks during test mode, solid with emergency/BMS input