content loaded
LEVITON X3120-YC Image 1

LEVITON X3120-YC X-SERIES TYPE 2 3-PH WYE SURGE PANEL

MFR Part #:Ā X3120-YC
SKU #:Ā 1279810
Brand:Ā LevitonĀ®
UPC:Ā 07847758309
LevitonĀ® X3120-YC X Series Type 2 Surge Protective Device, Electrical Ratings: 208Y/120 VAC, 50/60 Hz, 3 Phase, 12 AWG Wire
10 Years Limited
Indoor and Outdoor
ANSI/IEEE C-62.41.1-2002/C-62.41.2-2002/C-62.45-2002 Specified | CSA C22.2 No. 269.1-17, 2017-02 Certified | RoHS Compliant | UL 1449 5th Edition: 2021 Listed | cULus Listed | PROP65: This product contains lead, known to the State of California to cause cancer and birth defects or other reproductive harm

LevitonĀ®, X3120-YC, Surge Protective Device, Type 2, Series: X Series, 208Y/120 VAC Electrical Rating, 50/60 Hz Frequency, 3 ph, 12 AWG Wire, 200 kA Short Circuit, 200 kA Peak Surge Current, Modes of Protection: L-N/L-G/N-G/L-L, LED/Audible Alarm Indicator, Environmental Conditions: -40 to 60 deg C Storage Temperature, 0 to 95% Non-Condensing Humidity, NEMA 4X Enclosure, Surface Mounting, 3.25 in H x 9.47 in W x 8.14 in D Dimensions, Extruded Aluminum, White

Product Details

LevitonĀ®, X3120-YC, Surge Protective Device, Type 2, Series: X Series, 208Y/120 VAC Electrical Rating, 50/60 Hz Frequency, 3 ph, 12 AWG Wire, 200 kA Short Circuit, 200 kA Peak Surge Current, Modes of Protection: L-N/L-G/N-G/L-L, LED/Audible Alarm Indicator, Environmental Conditions: -40 to 60 deg C Storage Temperature, 0 to 95% Non-Condensing Humidity, NEMA 4X Enclosure, Surface Mounting, 3.25 in H x 9.47 in W x 8.14 in D Dimensions, Extruded Aluminum, White

Attributes

Color:Ā White
Country Of Origin:Ā US
Dimensions:Ā 3.25 in H x 9.47 in W x 8.14 in D
Electrical Ratings:Ā 208Y/120 VAC
Enclosure Type:Ā NEMA 4X
Environmental Conditions:Ā -40 to 60 deg C Storage Temperature, 0 to 95% Non-Condensing Humidity
Frequency Rating:Ā 50/60 Hz
Indicator Type:Ā LED/Audible Alarm
Material:Ā Extruded Aluminum
Modes of Protection:Ā L-N/L-G/N-G/L-L
Mounting Type:Ā Surface
Peak Surge Current:Ā 200 kA
Phase:Ā 3
Series:Ā X Series
Short Circuit Current Rating:Ā 200 kA
Type:Ā Type 2
Wire Size:Ā 12 AWG

Features

  • The maximum amount of current the device is capable of diverting to ground during a single surge event without performance degradation of more than 10%, Higher values are better
  • The amount of current the device can divert to ground 15 times under specific test conditions and maintain performance levels, Higher values are better
  • The maximum voltage a surge protector will let through to connected devices, Lower values are better
  • The maximum current a device or system can safely withstand for a specified time or until a specified fuse or circuit breaker opens and clears the circuit
  • Maximum line voltage (or V rms) that may be applied to the SPD without damaging the MOV, A lower MCOV rating allows for a lower VPR, but decreases the life of an MOV
  • A mode is a path that has an SPD component between two electrical points, More modes is better, 7-Mode example: L1-N, L2-N, L3-N, L1-G, L2-G, L3-G, N-G