content loaded
SQUARE D QO1515 Image 1

SQUARE D QO1515 PUSH-IN 15 AMP TANDEM BREAKER

MFR Part #: QO1515
SKU #: 0715100
Brand: Square D™
UPC: 785901400905
Square D™ QO™ QO1515 Tandem Miniature Circuit Breaker, 120/240 VAC, 15 A, 10 kA Interrupt, 1 Pole, Thermal/Magnetic Trip
18 months

Square D™ QO™ Miniature Circuit Breaker, Tandem, 120/240 VAC, 15 A, 50/60 Hz, 10 kA Interrupt, Thermal/Magnetic Trip, 1 Pole, 1 ph, Pressure Plate, 14 to 8 AWG Wire, Plug-On Mount, 104 deg F, 2.91 in L x 0.75 in W x 3 in H

Standard thermal-magnetic QO™ and Homeline™ 15 and 20 A circuit breakers are listed to UL489 and provide overload and short circuit protection for conductors. The QO™ and Homeline™ thermal-magnetic circuit breakers are for general use in protecting branch circuit in residential and commercial applications. Use QO™ and Homeline™ 15 and 20 A arc fault circuit interrupter circuit breakers that have been listed to UL1699 in order to provide arc fault circuit protection for the entire branch circuit in accordance with the installation requirements in National Electrical Code section 210.12. Thermal-magnetic circuit breakers are not designed, listed or intended to provide protection against low level hazardous arcing conditions in branch circuit wiring.

Product Details

Square D™ QO™ Miniature Circuit Breaker, Tandem, 120/240 VAC, 15 A, 50/60 Hz, 10 kA Interrupt, Thermal/Magnetic Trip, 1 Pole, 1 ph, Pressure Plate, 14 to 8 AWG Wire, Plug-On Mount, 104 deg F, 2.91 in L x 0.75 in W x 3 in H

Standard thermal-magnetic QO™ and Homeline™ 15 and 20 A circuit breakers are listed to UL489 and provide overload and short circuit protection for conductors. The QO™ and Homeline™ thermal-magnetic circuit breakers are for general use in protecting branch circuit in residential and commercial applications. Use QO™ and Homeline™ 15 and 20 A arc fault circuit interrupter circuit breakers that have been listed to UL1699 in order to provide arc fault circuit protection for the entire branch circuit in accordance with the installation requirements in National Electrical Code section 210.12. Thermal-magnetic circuit breakers are not designed, listed or intended to provide protection against low level hazardous arcing conditions in branch circuit wiring.

Attributes

Amperage Rating15 A
Number of Poles1
Connection TypePressure Plate
Dimensions2.91 in L x 0.75 in W x 3 in H
Frequency Rating50/60 Hz
Interrupt Rating10 kA
Mounting TypePlug-On
Phase1
Temperature Rating104 deg F
Trip TypeThermal/Magnetic
TypeTandem
Voltage Rating120/240 VAC
Wire Size14 to 8 AWG

Features

  • Al/Cu wire
  • Box lugs electrical connection
  • 14 to 8 AWG Al/Cu wire